Workshop Manual

Table Of Contents
© 02/2010 OBJ_DOKU-21811-001.fm
3/6
6
Electrical equipment
TCD 2013 2V W 48-02-01
Tighten screw (1).
9Nm
1
© 44089-0
Mount holder with impulse transmitter.
Clean the threads of the screws and holes.
Pay attention to different screw lengths.
Screw M8 x 45 mm (1)
Screw M8 x 40 mm (2)
Insert screws with safety agent
DEUTZ DW 72.
Do not tighten screws.
2
1
© 44091-0
Set gap dimension for impulse transmitter
(crankshaft)
Select feeler gauge.
0,6 mm
Push feeler gauge blade between tooth lock washer
and impulse transmitter.
Press the impulse transmitter lightly against the feel
-
er gauge blade.
© 44092-0
+0.1
- 0.1