Workshop Manual

Table Of Contents
© 02/2010 OBJ_DOKU-21799-001.fm
3/4
6
Thermostat housing
TCD 2013 2V W 38-02-01
Clean sealing surfaces.
Insert new sealing ring (arrow).
Coat the sealing ring with fitting compound.
© 44524-0
Push the coolant thermostat housing onto the adapt
-
er first.
Mount the coolant thermostat housing.
Tighten screws (arrows).
30 Nm
© 44525-0