Workshop Manual

Table Of Contents
© 02/2010 OBJ_DOKU-21789-001.fm
7/10
6
Injector
TCD 2013 2V W 19-01-01
When installing the injectors on
cylinders 1 to 5, the clamping shoe must
be inserted together with the injector.
In version with heating plugs:
Pay attention to perfect cable laying
(arrow).
© 48207-0
Mount clamping shoe.
Tighten screw.
Stage 1:
hand tight
Do not tighten the screw until after
assembling the injection line.
© 44031-0
Mount new injection line (1) on rail and injector.
Screw on union nuts.
Check the injection line for perfect installation posi
-
tion.
Attention!
The injection lines must always be
renewed after disassembly.
Install injection line without tension.
Note assignment and installation position
of the injection lines.
Do not tighten union nuts.
1