Workshop Manual

Table Of Contents
© 02/2010 OBJ_DOKU-21787-001.fm
6/10
6
High-pressure pump
TCD 2013 2VW 17-01-04
Install control block.
W 17-01-01
Tighten screws (arrows).
Stage 1:
10 Nm
Stage 2:
50 Nm
© 43979-0
Mount new high-pressure line on high-pressure
pump and rail.
Screw on union nuts (1).
Check the high-pressure line for perfect installation
position.
Attention!
The high-pressure line must always be
renewed after disassembly.
Install high pressure line without tension.
Do not tighten union nuts.
1
1
© 43980-0
Installation position of vibration damper.
Dimension X
Diameter: 32 mm
Attention!
Pay attention to installation position.
Do not turn vibration damper (1).
(1) Vibration damper
(2) Connection rail
(3) Connection high pressure pump
3
1
2
X
© 48208-0