Connecting rod
TCD 2013 2VW 06-01-02
Prepare internal measuring device:
Mount probe bolt for the appropriate measuring
range in the internal measuring device.
Mount dial gauge with approx. 1 mm pre-tension in
the internal measuring device.
Set micrometer gauge to 72 mm.
Balance the internal measuring device between
the test surfaces of the micrometer gauge and set
the dial gauge at the reversal point of the pointer to
"0".
© 36094-1
Diagram for measuring the con rod bearing
bore at the points "a" and "b" in the
levels "1" and "2".
© 37239-1
Insert internal measuring device.
Balance the internal measuring device at the given
measuring points and read off the measured value at
the reversal point of the pointer.
72,5 mm
If the measured values deviate slightly,
additional measurements must be made
with new bearing shells.
© 44214-0