Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Oil Level Float Switch
Testing
0178-48-10 1546
11.07.01 Page 1 of 2
S/BVM 628
Testing
With engine stationary, test switch response.
The switch is provided where required.
Where a high-level oil tank is fitted, the switch
gives alarm for maximum level; where lubrica-
tion is from the regular sump, the switch gives
alarm for minimum level.
Job
To begin with, open the following crankcase doors:
S/BV 6 M 628 S/BV 8 M 628 S/BV 9 M 628
Door 3 4 5
S/BV 12 M 628 S/BV 16 M 628
Cyl. bank A A
Door 3 4
Introduce wooden stick (e.g. a pencil) through one of the holes in top/bottom of switch and raise the latter
(high-level tank, Fig. 1) or press down (sump, Fig. 2), until alarm is released.
Job Card:
- 02.00.01
Tools:
- Standard tools
- Blunt wooden stick, 8 mm diameter,
about 100 mm in length
© 1283