Flow Switch (Fuel Injection)
Testing
0178-48-10 1191
11.01.03
S/BVM 628
Testing
Check that flow switch for shielded injection lines
works properly.
The switch can work properly only when the
fuel back leakage line is installed with consi-
stent gravity feed to the collector tank.
Alarm by the flow switch in service may be
caused by a broken line or a leaky connection.
Job
Clean switch (2) externally and make sure that con-
nections are tight.
With the engine in service, unscrew union (1) and take
out blanking cone. Put tundish on pipe connection and
fill in diesel fuel. The switch (2) should now release an
alarm as long as the diesel flow continues.
If no alarm is released, eliminate the cause of the
trouble or replace the switch.
Check that the electric lead is properly instal-
led so as not to “chafe”.