Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Pressure Transmitter
Noris VD 61 - 2,5
0178-48- 297 6502
Inspecting Pressure Transmitter
Pressure transmitters are available for the following
media, depending on the scope of monitoring equip-
ment:
lube oil, fuel, control air, starting and charge air pressu-
re. Settings are indicated on the pressure transmitter
in “bar”. The inspection is carried out during operation
according to the intervals specified in the Mainte-
nance Schedule. In the case of pressure transmitters
with measuring ranges different from that indicated
here, the inspection should be done analogously.
Job
Preparation
Clean housing (3).
Check that all bolts/screws are tight.
Check stuffing box screw union for possible leak (4).
Be sure no lead nor line can chafe!
Inspection
Close shut-off valve (1)
Remove screw plug (2), connect hose with test
connection. Fit a test gauge respectively a test
pump combined with pressure gauge to this
hose.
Connect ammeter.
Subject pressure transmitter with test pump to a
higher working pressure than specified - 6 bar at
a maximum, however.
Pressure transmitter must indicate on the con-
nected ammeter, depending on the measuring
range (e.g. 0-10 bar)
0 bar, corresponding to 4 mA,
6 bar, corresponding to 13,6 mA.
After Completed Inspection
Remove test hose.
Detach ammeter.
Turn in screw plug (2).
Open shut-off valve (1).
© 0185
11.01.02
S/BVM 628
Fig. 1
Calibration parameters for VD 61-2,5
Serial-Nr.: 1119202013 Day: 08-01-1992
Calibr.point 1
P1 = 0,000 bar
I1 = 4,01 mA Intermediate measurement
0,5 (P2 - P1) = 1,250 bar
Calibr.point 2
P2 = 2,500 bar Iout = 11.97 mA
I2 = 19,95 mA
Inp. range: 0...2,5 bar Output: 4...20 mA
Tools:
- Standard tools
- Test gauge
- Test hose with test connection
- Commercial test pump
- Ammeter (range 4-20 mA)
© 50 637 2