Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Pressure Reducer Station
Servicing
0178-32-10 1383
Servicing
Drain condensate and clean filter elements. This is
possible while the engine is running.
In hand lever position I and III, the H.P. lien is
connected to the L.P. line through one filter
and one pressure reducer each. The low pres-
sure is indicated by gauge (6) direct; it can be
adjusted with screws (5). In lever position II,
both filters and pressure reducers are connec-
ted in the L.P. line. In position IV, the H.P. lien is
isolated, while the L.P. line is connected to the
atmosphere.
Job
Draining Condensate
Operate rods (1).
Cleaning the Filter
Clean only filters not in service: filter(4) in lever
position I and filter (3) in position III.
With the engine shut down, both filters can be
cleaned in position IV.
Procedure
Unscrew plug and remove filter. After cleaning filter,
dry by air blast. Reinstall filter and fit plug with
washer.
10.06.01
S/BV M 628
Tools.
- Standard tools
© 1283
© 51 353 0