Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Dirt Collector
0178-32-10 1866
© 0484
10.03.02
S/BVM 628
Servicing
Before servicing the dirt collector in the starting air
line, make sure that the shut-off valve on the com-
pressed air receiver is closed.
Daily:
Open shut-off valve (1) on dirt collector and allow
condensation water (if any) to drain off. Then reclose
shut-off valve.
Clean the Sieve
as per Maintenance Schedule.
Job:
Loosen hex. nuts (3) and take out hex. bolts (2). Take
off flange (4) and gasket (5). Remove sieve (6). Clean
sieve with a cleaning agent (e.g. cold cleaner) and
rinse afterwards with fresh water. Then blow out with
compressed air. Renew sieve if damaged. Clean
sealing faces of flange and check gasket (5), rene-
wing if necessary. Centre sieve together with retainer
(8) in flange (4) and introduce assembly into tube (7),
taking care that the sieve also sits in the centring of
tube (7).
Now tighten hex. bolts (2) and hex. nuts (3).
Close shut-off valve (1), if open.
Direction of flow
Tools:
- Standard tools,
- Cleaning agent
© 25 234 1