Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Exhaust Elbow
0178-41-297 6504
© 0199
06.01.03
S/BVM 628
Inspection
Check exhaust elbow inside for corrosion damage.
- Initially after 24000 running hours
- Thereafter every 12000 running hours
Job
Illuminate elbow inside using flashlight.
If corrosion damage (1) is visible inside of
elbow, measure wall thickness with an ul-
trasonic tester.
DEUTZ Service will be at your disposal for
such purpose.
If the wall thickness is < 3 mm, the exhaust elbow
must be renewed; otherwise coolant leakage may
occur which again may result in water shock.
Tools:
- Flashlight
- Special tool
- Ultrasonic tester (see Section 1.8.1)
© 50 647 0