11. Adjust linkage at points C8 (*) or C10 (**) - Fig.
17 - so as to obtain the settings scheduled in
table at right. Then tighten all locknuts.
Fig. 16
Graduation
Actuator Injection Pump
9° from Stop 0
Stop limit position - 2,5 to - 5
34° from Stop approx. 14
Typical setting
Section A - B
Governor
Injection Pump
© 24 937 1
© 24 951 1