Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Woodward UG8D/UG8L Hydraulic Governor Linkage
Setting
0178-29-10 1809
© 1283
15. Setting the starting fuel limit:
While the engine is running at 11 bar b.m.e.p.,
pressurize air cylinder of fuel limit and adjust
refitted lever so that there is contact at point
(**) - Fig. 20 - . Tighten screw (*), depressurize
air cylinder.
After finally completing the settings, refit the
covers at points A22, A25, A23 and A26 - Fig.
1 -, together with new gaskets, if necessary.
Remount the linkage covers.
Fig. 20
05.04.14 Page 12 of 12
S/BV 9 M 628
© 24 940 1