Woodward UG8D/UG8L Hydraulic Governor Linkage
Setting
0178-29-10 1808
05.04.14 Page 12 of 12
S/BV 6/8 M 628
© 0583
15. Setting the starting fuel limit:
While the engine is running at 11 bar b.m.e.p.,
pressurize air cylinder of fuel limit and adjust
refitted lever so that there is contact at point
(**) - Fig. 20 - .
Tighten screw (*), depressurize air cylinder.
After finally completing the settings, refit the
covers at points A21 and A24 - Fig. 1 -,
together with new gaskets, if necessary. Re-
mount the linkage covers.
Fig. 20
© 24 940 1