Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Woodward UG8D/UG8L Hydraulic Governor Linkage
Setting
0178-29-10 1808
© 0583
05.04.14 Page 11 of 12
S/BV 6/8 M 628
Fig. 19
Fig. 18
12. Set stop screw A13 so that load indicator on
injection pump points to graduation (14) - Fig.
18.
13. Check that linkage abuts at stop screw (*) -
Fig. 19 - when pushed to maximum load (point
A13).
Upon completion of the setting, lead-seal the
engine output (**).
14. After the engine has been put back to service
and final load setting has been made, check
that the governor scale gives the following
readings:
No load = graduation 2
Full load = graduation 8
Failing this, adjust linkage (points C8 or C10
under 11.).
© 24 938 1
© 24 939 1