Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Woodward UG8D/UG8L Hydraulic Governor Linkage
Setting
0178-29-10 1808
05.04.14 Page 6 of 12
S/BV 6/8 M 628
© 0589
Then, at the right-hand end of the link (*) (point A24), adjust the length of the link by means of the
eccentric (**) so that the control rods contact the check stops without pressure, with the gauges
inserted (see Fig. 7). Insert new cheese-head screws according to tightening specification, see
"Specification Data", Section 3.5, line 60. If the setting at the right-hand eccentric is insufficient , rectify
at the left-hand eccentric.
Having completed the setting, the cheese-head screws have to be lead-sealed.
7. Remove tools (Fig. 7). Move linkage in the
direction "Stop" until one or more stop screws
abut at points C12 and C13 (Fig. 9).
Fig. 8
Fig. 9
© 24 931 1
© 24 973 3