Regulateurs Europa Ltd. Hydraulic Governor Linkage
Setting
0178-29-10 1807
05.04.14 Page 11 of 11
S/BV 9 M 628
© 0583
15. Setting the starting fuel limit:
While the engine is running at 11 bar b.m.e.p.,
pressurize air cylinder of fuel limit and adjust
refitted lever so that there is contact at point
(**) - Fig. 17 - . Tighten screw (*), depressurize
air cylinder.
After finally completing the settings, refit the
covers at points A22, A25, A23 and A26 - Fig.
1 -, together with new gaskets, if necessary.
Remount the linkage covers.
Fig. 17
© 24 940 1