Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Regulateurs Europa Ltd. Hydraulic Governor Linkage
Setting
0178-29-10 1807
© 0583
05.04.14 Page 10 of 11
S/BV 9 M 628
Fig. 16
Fig. 15
12. Set stop screw A13 so that load indicator on
injection pump points to graduation (14)
- Fig. 15.
13. Check that linkage abuts at stop screw (*) -
Fig. 16 - when pushed to maximum load (point
A13).
Upon completion of the setting, lead-seal the
engine output (**).
14. After the engine has been put back to service
and final load setting has been made, check
that the governor scale gives the following
readings:
No load = graduation 2
Full load = graduation 8
Failing this, adjust linkage (points C8 or C10
under 11.).
© 24 938 1
© 24 939 1