Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Regulateurs Europa Ltd. Hydraulic Governor Linkage
Setting
0178-29-10 1807
© 0484
05.04.14 Page 5 of 11
S/BV 9 M 628
Fig. 7
5. Use tools (*) - Fig. 7 - to pull control rods of all injection pumps against the gauges (**) contacting check
stops (***) at points A18, A19 and A20.
Leave tools (*) mounted for the time being.
6. Setting the Linkage
Mount the linkage in the reverse order as described for "Removing the Linkage when Removing
Injection Pumps", but do not yet tighten the new cheese-head screws (***) - Fig. 8 -.
First of all, turn the eccentric (**) at the left hand end of the link (*) (points A22, A23) to the middle
position, i.e., with the slit in the eccentric horizontal. Insert new cheese-head screws (***) and tighten
according to specification, see "Specification Data", Section 3.5, line 60.
© 24 929 1