Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Regulateurs Europa Ltd. Hydraulic Governor Linkage
Setting
0178-29-10 1806
05.04.14 Page 11 of 11
S/BV 6/8 M 628
© 0595
15. Setting the starting fuel limit:
While the engine is running at 11 bar b.m.e.p.,
pressurize air cylinder of fuel limit and adjust
refitted lever so that there is contact at point
(**) - Fig. 17 - .
Tighten screw (*), depressurize air cylinder.
After finally completing the settings, refit the
covers at points A21 and A24 - Fig. 1 -, toge-
ther with new gaskets, if necessary. Remount
the linkage covers.
Fig. 17
© 24 940 1