Regulateurs Europa Ltd. Hydraulic Governor Linkage
Setting
0178-29-10 1806
© 0583
05.04.14 Page 10 of11
S/BV 6/8 M 628
Fig. 16
Fig. 15
12. Set stop screw A13 so that load indicator on
injection pump points to graduation (14) - Fig.
15.
13. Check that linkage abuts at stop screw (*) -
Fig. 16 - when pushed to maximum load
(point A13).
Upon completion of the setting, lead-seal the
engine output (**).
14. After the engine has been put back to service
and final load setting has been made, check
that the governor scale gives the follo-
wing readings:
No load = graduation 2
Full load = graduation 8
Failing this, adjust linkage (points C8 or C10
under 11.).
© 24 939 1
© 24 938 1