Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Regulateurs Europa Ltd. Hydraulic Governor Linkage
Setting
0178-29-10 1806
05.04.14 Page 4 of 11
S/BV 6/8 M 628
© 1283
Synchronizing the Injection Pumps
2. Detach link C1 at point A5 (*) - Fig. 4 -.
3. Fully screw in stop screw (*) at point A 13 - Fig.
5 -. Record screw setting (**) where linkage is
adjusted repeatedly.
4. Release screw (*) - Fig. 6 - to remove lever on
starting fuel allowance stop, point A17.
Fig. 4
Fig. 5
Fig. 6
© 24 926 1
© 24 928 1
© 24 927 1