Operation Manual

Table Of Contents
Job Card No.:
Engine:
Filing No.:
Valve Rotator Inspection
© 1083
0178-11-10 1797
01.03.01
S/BVM 628
Inspection
Every 250 hours check while engine is running that
exhaust valves rotators move freely.
Job:
Unscrew plug (1) and O-seal (2) from rocker chamber
cover (3). Check with lamp that rotator (4) moves
freely: at 700/min engine speed check time needed
for a full revolution by watching cam (5). If this time is
more than 40 seconds, replace rotator on the next
occasion since rotator will most likely be out of
function soon.
Where rotator fails to move at all, replace once
engine can be stopped.
For rotator reconditioning see job 01.03.02. If O-seal
(2) is defective, replace.
Screw plug with O-seal into rocker chamber cover
and tighten moderately.
Tools:
- Standard tools,
- Lamp,
- Clock
© 25 466 1