Service Manual

Table Of Contents
3
3.5 Stop process
Operation
21
Shutting down
Avoid switching-off from full load ope-
ration (coking/blockage of the remai-
ning oil in the turbocharger bearing
housing)
Lubricating oil is no longer supplied to
the turbocharger!
Run the engine after relieving the load
for about 1 minute at low idling speed.
The control unit remains active for
about another 40 seconds to save the
system data (lag) and then switches off
automatically.
Electrical shutdown (optional)
z
Move the key to position 0. Pilot lamps
A+B+C go out.
A
B
C