Workshop Manual

Table Of Contents
© 12/2008 17842-001
4/8
6
D 2011 wOther components
TD 2011 w, TCD 2011 wW 12-02-01
z Mount V-belt tension measuring device on V-belt.
The V-belt must be between the
guides (arrow).
© 46997-1
z Press the V-belt measuring device against the V-belt
with the button (1) until you hear it click.
z Read measured value at the intersection (arrow) of
the indicator arm and scale.
450 N
z If the nominal value is not reached, the tensioning
process must be repeated.
Note different units on the scale.
© 46997-0
+50
50
z Tighten screws (1).
34 Nm
z Tighten screw (2).
22 Nm
300 N
The V-belt tension of new V-belts must be
checked after they have been running for
15 minutes.
2
1
© 46987-2
+20
20