Workshop Manual
© 02/2006 5997-001
1/2
D 2008/2009
Drive system
W 02-01-04
6
Checking the axial clearance of the crankshaft
8190
Commercial available tools:
– Magnetic measuring stand
– Micrometer gauge
Special tools:
– Dial gauge. . . . . . . . . . . . . . . . . . 100400
Checking the axial backlash
z Mount magnetic measuring stand.
z Insert dial gauge.
z Apply stylus to the crankshaft end with pre-tension.
z Press crankshaft in direction of arrow.
z Adjust dial gauge to "0".
© 41158-1
z Push crankshaft in the direction of the arrow and read
off the value on the meter.
P02 34
z Compare actual value with setpoint value.
z Remove magnetic measuring stand.
z Remove dial gauge.
1
© 41159-1