Workshop Manual
© 02/2006 6025-001
3/4
D 2008/2009
Electrical system
W 13-02-03
6
Check V-belt tension with V-belt tension
measuring device
z Lower indicator arm (1) into V-belt tension measuring
device.
z Mount V-belt tension measuring device on V-belt.
1
© 41129-0
z Press the V-belt measuring device against the V-belt
with the button (1) until you hear it click.
z Read the measured value at the point of intersection
of the indicator arm and the scale (arrows).
P12 11
P12 21
z If the nominal value is not reached, the tensioning
process must be repeated.
Note different units on the scale.
1
© 41130-0
z Remove cable from generator.
z Connect the battery's negative terminal.
© 41135-1