Workshop Manual
D 2008/2009
Cooling system
W 09-08-01
© 02/2006 6021-001
2/2
6
z Heat up the coolant thermostat in the water bath.
In order to determine the exact beginning
of opening, the temperature should be
measured as close as possible to the ther-
mostat without touching it.
The water should be continuously stirred
for an even temperature distribution. The
temperature rise should not take place
faster than 1°C/min. Otherwise the begin-
ning of opening will be delayed accordin-
gly.
© 41123-0
z Measure dimension "b" on the coolant thermostat.
„b“ = end of stroke at 99 °C - 102 °C
Stroke distance at given temperature at
least 8 mm.
b
© 41122-0
z Install the coolant thermostat.
W 09-08-02
© 41120-0