Service Manual
Table Of Contents
6
© 2001
6.9 Additional Maintenance Work Service and Maintenance
Test step 2
● Loosen screw 1.
● Turn engine over with starter, key in switch-
ing position 3.
● Fuel must be present on the loosened pipe
connection. Otherwise, the system and
solenoid valve should be checked by a
specialist!
Test step 3
● Loosen screw 1.
● Remove glow lamps 2
● Turn engine over with starter, key in switch-
ing position 3.
● Fuel must be present on the glow lamps 2,
or replace glow lamps 2 if necessary.
● When fitting glow lamps 2, use DEUTZ DW
47 sealants.
● Reinstall glow lamps to fuel line.
Keep away from moving parts!
Collect any escaping fuel and
dispose of this in an environ-
mentally-friendly manner.
© 24 717 1
© 24 717 1