6.9 Additional Maintenance Work Service and Maintenance
Test step 2
Loosen screw 1.
Turn engine over with starter, key in switch-
ing position 3.
Fuel must be present on the loosened pipe
connection. Otherwise, the system and
solenoid valve should be checked by a
specialist!
Test step 3
Loosen screw 1.
Remove glow lamps 2
Turn engine over with starter, key in switch-
ing position 3.
Fuel must be present on the glow lamps 2,
or replace glow lamps 2 if necessary.
When fitting glow lamps 2, use DEUTZ DW
47 sealants.
Reinstall glow lamps to fuel line.
Keep away from moving parts!
Collect any escaping fuel and
dispose of this in an environ-
mentally-friendly manner.
© 24 717 1