Workshop Manual

Table Of Contents
© 01/2009 OBJ_DOKU-23533-001.fm
4/6
6
D 2011Other components
TD 2011W 12-02-01
Mount V-belt tension measuring device on V-belt.
The V-belt must be between the
guides (arrow).
© 47480-0
Press the V-belt measuring device against the V-belt
with the button (1) until you hear it click.
Read measured value at the intersection (arrow) of
the indicator arm and scale.
450 N
If the nominal value is not reached, the tensioning
process must be repeated.
Note different units on the scale.
1
© 47458-0
+ 50
− 50
Tighten screw (1).
–M8
31 Nm
Hold locking nut (arrow).
Tighten screw (2).
43.5 Nm
300 N
The V-belt tension of new V-belts must be
checked after they have been running for
15 minutes.
2
1
© 47473-0
+ 20
− 20