Workshop Manual

0312 1578 - 0138
14/18
© 11/2004
6
Crankcase
W 03-08-03
2011
z Insert meter in measuring bridge and position the
stylus with pre-tension on the ball bearing (1).
z Adjust meter to "0".
© 33965 1
1
z Move the measuring bridge and position the stylus
on the ball bearing (1).
z Read and note measured value.
Note
The difference between both measured
values is max. 0.05 mm.
To achieve the required tolerance shims of
max. 0.5 mm may be placed under one stud
bolt.
© 33966 1
1
z Compensate the tolerance by using shim discs (1) of
suitable thickness.
z Repeat the measuring process after setting.
© 33963 1
1
1