W 01-01-01
W 01-01-01 Check and set valve clearance
Tools
- Commercial tools
Feeler gauges
Note
The standard valve clearance setting is
possible:
- On cold or warm engine after a cooling
time of at least 0.5 h.
- Oil temperature < 80 °C.
Removal
z Unscrew screws (arrows), remove starter cylinder
head cover (1) and gasket.
© 39131 0
1
Set engine to valve overlap
z Turn crankshaft until reaching valve overlap on
cylinder no. 1.
© 39132 0
01 63
© 11/2004 0312 1555 - 0138