Workshop Manual

0312 1600 - 0138
2/6
© 11/2004
6
Fuel system
W 07-07-05
2011
Testing the opening pressure
z Press down the lever of the nozzle tester slowly, with
connected pressure gauge.
The pressure at which the pointer stands still or
suddenly drops is the opening pressure.
© 36293 1
07 52
Note
- When the hand lever of the nozzle tester has
been actuated three or four times, the
pressure in the spring space has built back
up.
- The nozzle clamping nut must be loosened
again and re-tightened.
- The test must be repeated.
- If the measured values of three tests are
identical, these can be considered valid.
z Remove the injection valve from the nozzle tester.
© 36293 1
07002
Setting the opening pressure on the injection valve
z Insert the injection valve in the holder, unscrew the
nozzle clamping nut and remove all parts.
© 36270 1