Workshop Manual

Crankcase
W 03-08-03
0312 1577 - 0138
17/24
© 11/2004
6
2011
z Move the measuring bridge and position the stylus
on the ball bearing (1).
z Read and note measured value.
Note
The difference between both measured
values is max. 0.05 mm.
To achieve the required tolerance shims of
max. 0.5 mm may be placed under one stud
bolt.
© 39280 0
1
z Compensate the tolerance by using shim discs (1) of
suitable thickness.
z Repeat the measuring process after setting.
© 39633 0
1
1
z Unscrew nuts and remove regulator lever shaft.
z Push the adjustment lever (1) onto the regulator
lever shaft (2).
Note
Note installation position of the adjustment
lever.
© 33967 1
2 1