Workshop Manual
Crankcase
W 03-08-01
0312 1576 - 0138
7/12
© 11/2004
6
2011
z Plug the cable plug (2) to the engine shutdown and
tighten the screw (1).
z Plug the cable plug (3) to the lifting magnet for start
volume release.
© 39298 0
1
2
3
z Clean the sealing surface on the hydraulic pump
console and crankcase.
z Insert new round sealing ring (arrow).
© 39451 0
z Check all clamping sleeves are in place (arrows).
© 39452 0