Workshop Manual

1/4
6
2011
Drive system
W 02-09-07
W 02-09-07 Check piston
Tools
- Commercial tools
Micrometer gauge
Internal measuring device
- Special tools
100 400 - Meter
Note
If the wear limit is reached, the piston has
to be changed.
References
- W 02-09-03
Check the piston bolt bore
z Remove piston from con rod.
Î Job card W 02-09-03.
© 39054 0
Prepare internal measuring device
z Mount probe bolt for the appropriate measuring
range in the internal measuring device.
z Mount meter with approx. 1 mm pre-tension in the
internal measuring device.
z Set micrometer gauge to
- 26 mm in FL/M engines
- 30 mm in BFL/M engines.
z Balance the internal measuring device between the
test surfaces of the micrometer gauge and set the
meter to the reversal point of the pointer to ”0”.
© 34768 1
© 11/2004 0312 1571 - 0138