Workshop Manual

Drive system
W 02-03-01
0312 1567 - 0138
3/8
© 11/2004
6
2011
Check the con rod bearing bore
z Mount con rod bearing cover on con rod.
Note
The numeric identification (1) on the con rod
and the con rod bearing cover must be
identical and be opposite each other in
assembly.
© 39322 0
1
z Tighten nuts.
Note
Use a twelve-edge box wrench.
© 39323 0
02020
Prepare internal measuring device
z Mount probe bolt for the appropriate measuring
range in the internal measuring device.
z Mount meter with approx. 1 mm pre-tension in the
internal measuring device.
z Set micrometer gauge to 58.50 mm.
z Balance the internal measuring device between the
test surfaces of the micrometer gauge and set the
meter to the reversal point of the pointer to ”0”.
© 36094 1