Workshop Manual

Drive system
W 02-01-07
0312 1564 - 0138
3/4
© 11/2004
6
2011
Check runout
z Attach magnetic measuring stand and insert meter.
z Apply stylus to the main bearing pin with pre-tension
(arrow) and set meter to ”0”.
z Turn crankshaft evenly and check shells.
z Remove magnetic measuring stand and meter.
© 39180 0
02 26
Measure fit bearing width
z Set micrometer gauge to 35 mm.
z Push the internal measuring device between the test
surfaces of the micrometer gauge and set to ”0”.
© 35825 1
z Measure fit bearing width with internal measuring
device between the contact surfaces of the starting
rings.
z Note the measured value (dimension ”A”).
Note
The dimension "A" is required for determining
the axial clearance.
© 39181 0
02 11 02 12 02 13