Service and Maintenance 6.7 Accessories
6.7.1 Battery
6.7.1.1Checking Battery and Cable
Connectors
6.7.1.2Checking Electrolyte
Level
6.7.1.3Checking Specific
Gravity of Electrolyte
Keep battery clean and dry.
Undo dirty clamps.
Clean terminal posts (+ and –) and clamps of
the battery, and grease with acid-free and
acid-resistant grease.
When reassembling, ensure that clamps
make good contact. Do up clamp bolts finger
tight.
Remove caps 1.
If testers 2 are used, the electrolyte should
come up to their base.
If testers are not used, the electrolyte level
should be 10-15 mm above the top of the
plates.
If necessary, top up with distilled water.
Replace caps.
Measure the specific gravity of individual
cells with a commercial hydrometer.
The hydrometer reading (see table on
following page) indicates the state of charge.
During measurement, the temperature of the
electrolyte should preferably be 20°C / 68°F.