6.4.4 Dry Type Air Cleaner
Dust Discharge Valve
Filter Cartridge
Empty dust discharge valve 1 by pressing
apart lips of discharge slot as indicated
by arrows.
Clean discharge slot from time to time.
Remove any caked dirt by pressing
together the upper section of the valve.
Undo clip fasteners 1.
Take off hood 2 and remove cartridge 3.
Clean cartridge (replace at least once a
year).
Clean cartridge 3:
Blow out from inside out with dry com-
pressed air (max. 5 bar), or
in difficult cases, tap out, taking care
not to damage the cartridge, or
wash according to manufacturer’s
instructions.
Check paper filter (light showing through)
and gaskets for damage. Replace if
necessary.
After five air cleaner services or after
two years at the latest, replace safety
cartridge 4 (never clean).
To do so:
Undo hex. nut 5 and remove cartridge 4.
Install new cartridge, insert and tighten
hex. nut.
Install cartridge 3, replace hood 2 and do
up clip fasteners.
Never clean filter cartridge
with gasoline or hot fluids.
!
© 25 888 1
© 25 889 0
Service and Maintenance 6.4 Combustion Air Cleaner