Operation Manual

6
© 2002
Never clean air cleaner with
gasoline. Dispose of old oil in
accordance with environmen-
tal regulations.
6.4.2 Emptying Cyclone Type
Precleaner
Turn engine off and wait about 10 minutes
for the oil to drain from filter housing 1.
Release snap clips 2 and remove oil cup 3
together with filter element 4. If necessary
prize element out with a screwdriver,
taking care not to damage the rubber
gasket 5.
Remove dirty oil and sludge. Clean oil cup.
Clean filter element 4 in diesel fuel and
allow to drip-dry.
Undo wing nut 1 and remove cover 2.
Remove collector bowl 3 from lower sec-
tion 4 and empty. Clean leaves, straw and
other foreign matter from lower section of
precleaner.
Reposition collector bowl 3 onto lower
section 4, fasten cover 2 in place by
tightening wing nut 1.
Clean filter housing 1 if very dirty.
Inspect and replace rubber gaskets 5 and
6 if necessary.
Fill oil cup with engine oil up to the mark
(arrow) (for viscosity, see 4.1.2).
Refit oil cup and element to filter housing
and secure with snap clips.
6.4.3 Cleaning Oil Bath Air
Cleaner
Never fill collector bowl with oil. Replace
collector bowl if damaged.
© 25 886 0 © 25 887 0
!
6.4 Combustion Air Cleaner Service and Maintenance