6
© 2002
Service and Maintenance 6.3 Cooling System
© 30 299 0
1
2
0297 4985 1
BFM 1013E
1013 E
Short engine
Loosen vent plug position 2 and sealing plug
position 3.
Add coolant up to the maximum marking or
filler limit (heater valve of the system must be
opened – if fitted).
Tighten vent plug position 2 + sealing plug
position 3.
Close radiator cap position 1.
Start engine and warm up until thermostat
opens.
Switch off engine.
Check coolant level when the engine is cold
and top up as required.
Close the radiator sealing plug position 1.
Venting
The cooling systems, which are built in line
with our installation guidelines, are vented
automatically after they have been filled.
With external cooling systems in accordance
with the specifications of the manufacturer.
Start the engine and warm up until the
thermostat opens.
6.3.7 Draining the Cooling System
Unit Engine (4 Cylinders)
Open the cap 1 of the expansion tank.
Place a container beneath knurled screw 2.
Unscrew the knurled screw 2 in an anti-
clockwise direction until coolant is emitted.
Drain off coolant.
In case of clogging, rinse the radiator through
with clear water.
Tighten knurled screw 2.
Filling/venting the cooling system:
see section 6.3.8