19.3.2 Emptying the water supply line of the macerator toilet
Blow compressed air through the water pipes.
Close the water tap of the macerator toilet (Fig. 184,3).
Remove the pipe hose at the bayonet fitting of the toilet (Fig. 184,2).
Connect the additional drain hose which leads to the outside to the bayonet fit-
ting of the toilet (Fig. 184,2).
Open the water tap of the macerator toilet (Fig. 180,3).
Blow compressed air through the water supply line of the macerator toilet and
flush the toilet at the time.
Wait until no water comes out of the hose.
Remove the compressed air.
Close the main stopcock at the pressure reducer (Fig. 173,1).
Close the water tap of the macerator toilet (Fig. 184,3).
19.3.3 Emptying macerator toilet
Press the flush button at the toilet 3x to pump out the residual water.
Pour 350 ml commercial antifreeze (-30 °C) into the toilet.
Remove the plug (Fig. 184,1) of the macerator toilet out of the socket.
19.3.4 Emptying the boiler
Open the red drain valve (Fig. 177,4).
The boiler drain completely.