Operation Manual

Showmen package
19
206 Caravan - 14-09 - EN
19.2.4 Putting the instantaneous water heater into operation
The showmen packages 2 and 4 include an instantaneous water heater for water
heating.
Putting the instantaneous
water heater into operation
Close the red drain valves (Fig. 179,1).
Open the black valves (Fig. 179,2).
Switch off the fuses F1-F3 (Fig. 170).
Open the hot water tap that is furthest away from the pressure reducer and wait
until water flows out.
Close the water tap.
Open all the further hot water taps in the caravan and wait until water flows out.
The instantaneous water heater is filled.
Close the water tap.
Establish a 400 V connection at the caravan.
Switch on the FI-switch and fuses F1-F3 (Fig. 170).
Carry out the settings in accordance with the manufacturer specifications.
19.2.5 Putting the macerator toilet into operation
Connect the waste water connection of the toilet to the faeces drain of the site.
Connect the bayonet fitting (Fig. 180,3) of the toilet.
Open the water tap (Fig. 180,4).
Z Before the instantaneous water heater is connected to the current supply, the
water pipes and the instantaneous water heater have to be filled with water.
Fig. 178 Fuse box Fig. 179 Instantaneous water heater
F1
F2
F3 F5 F7
F4 F6 F8 FI
2
2
1
1
Fig. 180 Connection of macerator toilet Fig. 181 Flush button of macerator toilet
1
3
4
2