Operation Manual
Showmen package
19
204 Caravan - 14-09 - EN
19.2 Putting the showmen package into operation
19.2.1 Establishing the mains water connection to the caravan
Close the inspection glass (Fig. 173,2) at the pressure reducer.
Close the main stopcock at the pressure reducer (Fig. 173,1).
Close all the water taps, stopcocks and drain valves.
Check the pressure reducer setting of 2 bars (boiler version) or 3 bars (instanta-
neous water heater version) (Fig. 174,1).
Connect fresh water to the bayonet fitting (brass piping, Fig. 175).
Connect the waste water to the waste water connection (plastic piping,
Fig. 176).
Z In order to avoid damage to the vehicle, observe the order during connecting.
Z The pressure reducer is preset to 2 or 3 bars respectively depending on the
package and may not be adjusted.
Fig. 173 Pressure reducer (main stopcock
closed)
Fig. 174 Pressure reducer setting
2
1
Fig. 175 Fresh water connection (brass
piping)
Fig. 176 Waste water connection (plastic
piping)
Z Do not confuse the connections. Otherwise fresh water can be pressed through