Operation Manual
Showmen package
19
203Caravan - 14-09 - EN
19.1.4 Power cable for external 400 V connection
Power cable
z Depending of the length, five-conductor (5x10 - 5x16 mm
2
) flexible rubber
sheathed cable
z 1 plug with earth contact
z 1 socket with earth contact (connectors to EN 60309)
Connection possibilities We recommend a CEE 32 A connection cable with CEE 32 A plug and CEE 32 A
socket as the supply line.
Connecting the power cable:
Open the cover (Fig. 172,2) of the CEE 32 A connecting cable.
Plug the plug into the 400 V socket (Fig. 172,1) of the caravan.
Plug the plug (Fig. 172,3) into the socket of the 400 V power supply unit at the
site.
Switch on the FI-switch at the caravan.
Check whether the fault-current protection switch in the caravan functions by
pressing the test button (pushbutton next to the FI switch) and switch it back
on.
Disconnecting the supply line:
Switch off the FI-switch at the caravan.
Remove the plug from the socket of the 400 V power supply unit at the site.
Remove the plug at the 400 V socket of the caravan.
X Check cables/lines, plugs and connections for damage.
X Switch all the fuses and FI-switches in the caravan off before the caravan is
connected to the power supply.
Fig. 172 Connection options for 400 V
connection
2
1
3
Z Before the 400 V connection to the outside is established, all the fuses and the
FI-switch have to be switched off.
Z If the power supply is not established after the fuses have been switched on,
inform the site operator.
Z Depending on the model, unlock the plug before pulling it out.