Operation Manual

Troubleshooting
16
182 Caravan - 14-09 - EN
16.7.2 Refrigerator Thetford N3000
16.8 Air conditioning unit
16.8.1 Teleco
16.8.2 Dometic
Fault Cause Remedy
Refrigerator does not work Refrigerator is not plugged
in
Check the connections and
connect the refrigerator
Refrigerator is switched off Switch the refrigerator off
and on again
Refrigerator does not
switch on when operating
in 240 V mode
No 240 V power supply Connect 240 V power sup-
ply
Switch to a different ener-
gy source
Refrigerator does not
switch on when operating
in 12 V mode
12 V fuse on the starter
battery is defective
Check the fuse and re-
place if necessary
The engine is not running Switch on the engine and
change to a different ener-
gy source if necessary
Refrigerator does not
switch on when operating
in gas mode
Lack of gas Open regulator tap and
gas isolator tap
Connect a full gas bottle
Switch the refrigerator off
and on again
Switch to a different ener-
gy source
Fault Cause Remedy
Air conditioning unit does
not cool
No 240 V power supply Connect 240 V power sup-
ply
Fuse is defective Check fuse and replace if
necessary
Temperature below 16 °C
Temperature has been set
incorrectly
Adjust the temperature
Air filter soiled Replace the air filter
Fault Cause Remedy
Air conditioning unit does
not work
No 240 V power supply Connect 240 V power sup-
ply
Fuse is defective Check fuse and replace if
necessary
Air conditioning unit does
not cool
Temperature below 18 °C Adjust the temperature
Temperature has been set
incorrectly