Operation Manual
Maintenance
13
160 Caravan - 14-09 - EN
13.5.2 Topping up the heating fluid
Position the vehicle horizontally. This prevents formation of bubbles.
Switch off the hot-water heater and allow it to cool down.
Unscrew or remove the panel.
Unscrew the screw cap (Fig. 152,1) at the compensator reservoir.
Slowly remove the cover with circulating pump upwards.
Check anti-freeze with an anti-freeze hydrometer. The frost protection content
must be 40% or provide frost protection of up to -25 °C.
Fill the water frost protection mixture slowly into the compensator reservoir.
13.5.3 Bleeding the heating system
The bleeding valves are built in nearby the radiators.
Switch off the hot-water heater and allow it to cool down.
Open the bleeding valve (Fig. 153,1) and leave it open until no more air escapes.
Close bleeding valve.
Repeat this procedure at all bleeding valves.
Check to see if the hot-water heater warms up.
Z The heating fluid has to be renewed every 2 years.
Z The optimum fluid level is reached when the fluid in the compensator reservoir
is 1 cm above the "MIN" mark.
Fig. 153 Bleeding valve of hot-water
heater