Operation Manual
Appliances
10
105Caravan - 10-12 - EN
10.2.5 Alde hot-water heater
The hot-water heater has been fitted below in the wardrobe.
Operating unit The operating unit is divided into two sections:
z Display (touch screen)
z Control buttons
Control buttons The control buttons have the following functions:
Display The display (Fig. 109,1) is designed as a touch screen. Touching the symbols calls
up the relevant function.
Start screen The Start screen appears on the display after the heater is switched on. The Start
screen contains the following information:
Z Never run the hot-water heater without heating fluid. Observe the specifica-
tions in Chapter 13.
Z Never drill holes in the floor. This might damage the hot-water pipes.
Z Do not use the space above and behind the heater as a storage compartment.
Z The circulating pump must always be turned on when the hot-water heater is
in operation.
Z We recommend bleeding the heating system after the initial heater operation
to checking the glycol content. Observe the specifications in Chapter 13.
Z When the heater is turned on, it starts with the last settings used.
Z For further information, see the separate manufacturer's instruction manual
and observe the maintenance instructions found in Chapter 13.
Z For further information about the use of the boiler see Section "Boiler".
Fig. 109 Operating unit for hot-water
heater
1 Display (touch screen)
2 "Menu" button
3 On/Off button
Z If no button is pressed, the operating unit automatically switches to the home
position after two minutes.
Z Changes to the settings are saved automatically after 10 seconds.
No. in
Fig. 109
Button Function
2 MENU Open adjustment menu
3
Activate heating