9.8.2 Power cable for external 230 V connection
Power cable
z Three-core (3 x 2.5 mm
2
) flexible rubber sheathed cable
z Maximum 25 m in length
z 1 plug with earth contact
z 1 socket with earth contact (connectors to EN 60309)
Connection possibilities We recommend a CEE connection cable with CEE plug and CEE socket as the supply
line. If these connection possibilities are not available, we recommend the fol-
lowing combination with an isolated earth plug:
z Adapter cable:
CEE 17 socket with earth contact (Fig. 95,1) – Plug with earth contact (Fig. 95,2)
z Cable reel:
Socket with earth contact (Fig. 95,3) – Plug with earth contact (Fig. 95,4)
z Adapter cable:
Socket with earth contact (Fig. 95,5) – CEE 17 plug with earth contact (Fig. 95,6)
Depending on the model, the flap for the 230 V connection is identified with the
symbol " ".
Connecting the power cable:
Open the external flap.
Depending on the model, fold up the cover.
Plug in the plug:
X Completely unwind the cable on cable drums to prevent overheating.
Fig. 95 Connection options for 230 V
power connection
Fig. 96 Connecting an angled connector
with socket
X If a CEE 17 angled connector with socket mounted on rear (Fig. 96,1) is used,
use only a rubberised and sealed IP 44 plug with earth contact (Fig. 96,2). Do
not use a plug without earth contact (Fig. 96,3). Danger of electrocution!
Z Depending on the model, unlock the plug before pulling it out.